Permit: T07PL00159

Parcel: 131010460


Addresses:

5028 E 22ND ST #100

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
02/16/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
02/14/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
WATER TEST FROM BUILDING SEWER BACK UPSTREAM 4" THRU INTERCEPTOR TO END OF LINE CLEANOUT AND STUB UP FOR FLOOR DRAIN. INCLUDING INTERCEPTOR VENT.
1. SHALL HAVE MINIMUM FALL IN UNIFORM MANNER ON PIPING
2. SHALL SEE TRAFFIC RATED END OF LINE CLEANOUT & FLOOR DRAIN INSTALL PRIOR TO CONCRETE.
02/13/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
406--6178
TEST TO BE IN PLACE ON ALL PIPING
02/12/2007 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SHALL HAVE MINIMUM FALL ON ALL PIPING
2. SHALL SHADE ALL PIPING NO BRIDGING
3. SHALL HAVE TEST ON ALL PIPING
4. SHALL PROVIDE LONG RADIUS FITTINGS FOR VENT BELOW FLOOD RIM OF FIXTURE.