Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/27/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 02/27/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1. GAS TO WATER HEATER CAPPED OFF (ELECTRIC) ELECTRIC WATER HEATER INSTALLED WITHOUT PERMIT HOMEOWNER TO MAKE NECESSARY CORRECTIONS 2. WHEN FURNACE IS CHANGED, INSTALL NEW GAS VALVE 3. PRESSURE TEST OK 4. CORRECTIONS FROM 1/25/07 MADE OK OK FOR GAS UCC LEFT AT METER SET |
|
| 01/25/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. THIS IS NOT A RECONNECT 2. SUPPORT NEW PIPING W/PIPE CLAMPS AT 8' AND AT EVERY CHANGE OF DIRECTION. 3. TERMINATE PIPE AT METER LOCATION 21" ABOVE GRADE AND SECURE IT TO THE WALL. 4. PROVIDE ACCESS TO GAS APPLIANCES. 5. TEST W/AIR, USE A 15 PSI GAUGE. |