Permit: T07PL00127

Parcel: 120082050


Addresses:

244 W OHIO ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/06/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
1) GAS CARD ON PIPE AT METER
01/19/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE ENCLOSURE FOR WATER HEATER AND FLUE VENT AND CAP AND RUN T&P PIPING IN COPPER CPVC
2. TEST NOT HOLDING PROVIDE 1/10 LB TEST SETUP 0-15
3. ADD SUPPORT ON ALL GAS PIPING INSIDE AND OUTSIDE.
4. INSTALL NEW AGA SHUTOFF VALVE AND FLUE AT STOVE
5. PROVIDE SEDIMENT TRAP FOR FURNACE AND WATER HEATER.