Permit: T07PL00103

Parcel: 135040880


Addresses:

1726 S AVENIDA URSA

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/22/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
01/19/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. ALL UNDERGROUND PIPING SHALL BE FACTORY COATED TO PROTECT FROM RUST.
2. TEST GAUGE TO BE IN 1/10 POUND INCREMENTATIONS.
3. WATER HEATER TEMPERATURE & PRESSURE RELIEF SHALL BE FULL SIZE RIDGID APPROVED PIPING (NO FLEX KINKED) GRAVITY DRAN TO DAYLIGHT.
4. VENT FROM WATER HEATER TO HAVE 3-GALV SCREWS AT EACH JOINT.
5. PROVIDE CORRECT COMBUSTION AIR FOR WATER HEATER.
6. PROVIDE #4 BONDING WIRE.
7. SEAL ALL PIPE PENETRATION INTO BUILDING.
8. SHALL PROVIDE ROOF FLASHING FOR PIPE PENETRATION THRU ROOF.