Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07PL00013

Parcel: 128061380


Addresses:

5645 E BEVERLY ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/10/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
01/09/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PETITION OF APPEAL #2007-244 ON SITE
1. SHALL PROVIDE 1" AIR GAP FOR T&P DRAIN AND TOP OF PAN AT WATER HEATER.
2. SHALL TERMINATE 125# PRESSURE RELIEF IN DOWNWARD ANGLE WITH NIPPLE WITH NO THREADS ON DISCHARGE END.
3. PERMANENT CAP AND OR REMOVE OLD GAS PIPING.

1. SECURE GAS PIPING AT STOVE DROP AND ON ROOF AT CORRECT INTERVALS.
2. PROVIDE RATED FLEX TO MEET 110,000 BTU REQUIREMENT OF ROOFTOP UNIT THAT IS LONG ENOUGH TO REACH UNIT.