Permit: T07OT02545

Parcel: 117020840


Addresses:

1010 N 5TH AV #02


Inspection Status: Partial Approval

Inspection History: CERTIFICATE OF OCCUPANCY

Permit Number - T07OT02545

Inspection Description - CERTIFICATE OF OCCUPANCY

Inspection Status - Partial Approval

Date Description Inspector Results Comments
06/20/2008 CERTIFICATE OF OCCUPANCY Partial Approval IVRS - Inspection :*
04/18/2008 CERTIFICATE OF OCCUPANCY Partial Approval IVRS - Inspection :*
10, 11, 12 - DONE
2, 3, 8, 9, 13 - PARTIALLY DONE OR INCORRECT
1,4,5,6,7 - NOT DONE AT ALL
03/13/2008 CERTIFICATE OF OCCUPANCY Denied T07OT02545 & T07OT02546

1. PROVIDE PERMANENT ACCESSIBLE ROUTE FROM NORTH DRIVE SIDEWALK INTO COURTYARD ENTRANCE
2. LEVER HANDLE "NO KNOWLEDGE" HARDWARE REQUIRED ON ALL COMMON ROOMS (NO PRIVATE OFFICES)
NO KNOWLEDGE MEANS IT WILL UNLOCK FROM EGRESS SIDE WHEN HANDLE IS TURNED
3. ALL DEADBOLT LOCKS @ EXITS AND ON COMMON PATH OF TRAVEL SHOULD BE LEVER TYPE
4. INSTALL GRAB BARS PER ANSI 117.1
IN ALL ACCESSIBLE RESTROOMS
5. INSULATE DRAIN PIPE @ LAVATORY IN ALL ACCESSIBLE RESTROOMS
6. INSTALL SIGNAGE FOR ALL RESTROOMS
MAN/WOMAN BRAILLE AT ALL RESTROOMS PLUS WHEEL CHAIR DUDE ON ACCESSIBLE RESTROOMS
7. RAMP INTO POTTERY AREA REQUIRES CURB PROTECTION
2" STRAP WELDED 1" ABOVE RAMP SURFACE
8. REMOVE DOUBLE KEYED DEADBOLTS FROM EXIT DOORS
9. SELF CLOSER REQUIRED ON KILN ROOM DOOR
10. ANTI-SIPHONE DEVICES REQUIRED ON ALL HOSE BIBBS
11. INSTALL COVER ON ELECTRIC BOX IN FURNACE CLOSET
12. TEMP. PRESSURE RELIEF VALVE TO POINT DOWN AND TERMINATE 6" TO 18" ABOVE FLOOR IN MECHANICAL CLOSET
13. RELOCATE H.C PARKING SPACE @ REAR SO THAT YOU HAVE AN ACCESS AISLE - FRONT OF MECH CLOSET IS GOOD SPOT --- MOUNT H.C PARKING SIGN 84" ABOVE GRADE
14. COMPLETE ALL ITEMS NOTED BY FIRE INSPECTION.
03/04/2008 CERTIFICATE OF OCCUPANCY Partial Approval IVRS - Inspection :*