Inspection History Details
Inspection Status: Approved
Inspection History: CERTIFICATE OF OCCUPANCY
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/29/2008 | CERTIFICATE OF OCCUPANCY | Approved | IVRS - Inspection :* | |
| 01/29/2008 | CERTIFICATE OF OCCUPANCY | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ACCESSIBLE RESTROOM MUST HAVE LEVER HANDLE "NO KNOWLEDGE" HARDWARE AND SIGN TO BE MOUNTED 60" ABOVE FLOOR ON WALL AT LATCH SIDE. 2. CAULK ALL TOILETS @ FLOOR & LAVATORIES @ WALL 3. YOU MAY NOT RUN NEON LEIGHT CORDS ABOVE CEILING 4. USE PROPER LISTED AND LABELED EXTENSION CORDS FOR LIGHTS AND DO NOT RUN LIGHT CORDS ABOVE CEILING 5. KRAFT FACED INSULATION MAY NOT BE USED ABOVE CEILING IN AN EXPOSE MANNER YOU MUST EITHER REMOVE IT, FLIP IT AND PUT TO DECK OR COVER PAPER WITH UNFACED BUTTS 6. ALL INDIRECT WASTE TO TERMINATE 1" ABOVE FLOOR SINK 7. RP BACKFLOW DEVICE REQUIRED FOR CARBONATOR |