Inspection History Details
Inspection Status: Approved
Inspection History: CERTIFICATE OF OCCUPANCY
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/06/2008 | CERTIFICATE OF OCCUPANCY | Approved | IVRS - Inspection :* NO KNOWLEDGE HARDWARE INSTALLED |
|
| 02/27/2008 | CERTIFICATE OF OCCUPANCY | Not ready for Inspection | IVRS - Inspection :* DOORS MUST UNLOCK WHEN HANDLE TURNED @ EGRESS SIDE "NO KNOWLEDGE" HEALTH DEPT? |
|
| 01/29/2008 | CERTIFICATE OF OCCUPANCY | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. LEVER HANDLE "NO KNOWLEDGE" HARDWARE REQUIRED 2. 12" ADDRESS DISPLAY REQUIRED 3. ALL CLASSROOM EXIT DOORS MUST WORK 4. EMERGENCY EGRESS LIGHTING WITH BATTERY BACK UP REQUIRED 5. REMOVE SHADE @ FRONT OF BACK BUILDING 6. TPRO DISCHARGE TO TERMINATE 6" TO 18" FROM GROUND AT WATER HEATER 7. YOU MAY NOT HAVE DRINKING FOUNTAIN IN RESTROOM 8. HEALTH DEPT. APPROVAL REQUIRED (WILL ADD TO INSP. CARD) 9. POST "STORAGE ONLY" SIGN ON BASEMENT 10. GET FIRE ALARM APPROVAL |