Inspection History Details
Inspection Status: Denied
Inspection History: SIGN SHOP
Permit Number - T07OT01793
Inspection Description - SIGN SHOP
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/23/2007 | SIGN SHOP | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. SWITCHES NEEDED FOR SIGNS PER 600.6 2. SIGN CIRCUIT TO BE LABELED CORRECTLY AND SEPARATE AS PER 600.5 3. MARKING LABELS NEEDED FOR INTERIOR SIGNS 4. ISOLATE POWER TO SWITCH PILL CABINET 5. PROTECT CONDUCTORS FROM SHARP METAL EDGES 6. EXPOSED CONDUCTORS INTERIOR OF SIGN 7. MC TO TERMINATE PER MANUFACTURES INSTRUCTIONS |