Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07OT01645

Parcel: 13106008A


Addresses:

2001 S CRAYCROFT RD


Inspection Status: Approved

Inspection History: CERTIFICATE OF OCCUPANCY

Permit Number - T07OT01645

Inspection Description - CERTIFICATE OF OCCUPANCY

Inspection Status - Approved

Date Description Inspector Results Comments
08/06/2009 CERTIFICATE OF OCCUPANCY Approved IVRS - Inspection :*
07/08/2008 CERTIFICATE OF OCCUPANCY Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. WALLS WITHIN 2' OF TOILETS TO BE A HARD, IMPERMEABLE AND WASHABLE SURFACE
2. YOU MAY NOT TIE BEER TAP DRAIN TO LAVATORY TAILPIECE RUN TO APPROVED INDIRECT WASTE
07/25/2007 CERTIFICATE OF OCCUPANCY Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SODA CARBONATOR SHALL HAVE CORRECT BACKFLOW PROTECTION FOR WATER SUPPLY.
2. SHALL PROVIDE PERMIT FOR NEW GREASE TRAP, DRAINAGE FOR GREASE TRAP FROM 3-COMP SINK TO SANITARY DRAIN SHALL BE CORRECT
3. DRAINAGE FOR SANITIZE BOWL OF 3-COMP SINK SHALL GO TO INDIRECT DRAIN RECEPTOR, DRAINAGE FROM RECEPTOR TO BE INSTALLED CORRECTLY.
4. HAND SINK AT 3-COMP SINK LOCATION TO HAVE CORRECT DRAINS DIRECTLY CONNECTED TO SANITARY DRAINAGE SYSTEM.
5. DRAIN FROM WALK IN COOLER SHALL BE FULL SIZE AND TERMINATE CORRECTLY TO BRANCH TAILPIECE OF LAV OR INDIRECT WASTE RECEPTOR.
6. DRAIN FROM ICE MACHINE SHALL BE GRAVITY DRAIN FULL SIZE WITH MINIMUM 1" AIR GAP
7. SHALL PROVIDE CORRECT BACKFLOW PROTECTION FOR WATER SUPPLY TO ICE MACHINE OR PROOF OF 1" AIR GAP
8. SHALL PROVIDE CORRECT DRAINAGE FOR 3-COMP SINK AT BAR AREA IN WORKING ORDER
9. WATER HEATER TO HAVE APPROVED FIRM BASE BE IN WEATHERPROOF ENCLOSURES, HEATER TO HAVE TEMPERATURE AND PRESSURE RELIEF DRAIN TERMINATE AT DOWNWARD DIRECTION 6"-24" FROM FINISH GRADE. VENT TO BE PROPERLY INSTALLED FROM WATER HEATER.
10. GAS PIPING TO WATER HEATER TO BE SECURED
11. PROVIDE VENT FOR URINAL DRAINAGE WITH CORRECT TRAP
12. BOTH EXIT DOOR NEED SIGNS "DOORS TO REMAIN OPEN DURING BUSINESS HOURS"
13. REPLACE ALL BROKEN COVER PLATES @ ELEC. OUTLETS AND SWITCHES
14. ALL HOSE BIBS NEED VACUUM BREAKERS INSTALLED.