Inspection History Details
Inspection Status: Approved
Inspection History: CERTIFICATE OF OCCUPANCY
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/01/2007 | CERTIFICATE OF OCCUPANCY | Approved | IVRS - Inspection :* 1. OWNER LOCKED POOL GATE THAT DOESN'T WORK ALTERNATE EXIT OK 2. #12 AWG GREEN WIRE RUN TO BOND FENCE |
|
| 07/30/2007 | CERTIFICATE OF OCCUPANCY | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SEE NOTE 5 FROM 7/25 2. ALL METAL FENCING WITHIN 5' OF POOL EDGE MUST BE BONDED TO GROUND (= TO POOL METER) 3. PROPERLY LABEL SERVICE PANEL DISCONNECTS |
|
| 07/26/2007 | CERTIFICATE OF OCCUPANCY | Not ready for Inspection | IVRS - Inspection :* | |
| 07/25/2007 | CERTIFICATE OF OCCUPANCY | Not ready for Inspection | IVRS - Inspection :* 1. ALL HOSE BIBS MUST HAVE VACUUM BREAKERS 2. FRONT OUTSIDE ELEC. OUTLET MUST HAVE WEATHERPROOF COVER INSTALLED 3. WATER HEATER PRESSURE RELIEF VALCE LINE MUST BE REPLAED WITH A HARD PIPE WITH A DOWNWARDS SLOPE 4. ALL DOOR & GATES TO EXTERIOR CANNOT HAVE KEY LOCKS ON INSIDE 5. BOTH GATES TO POOL AREA MUST BE SELF CLOSING AND LATCHING |