Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07OT01360

Parcel: 13634796A


Addresses:

3731 S KOLB RD #02


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T07OT01360

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
10/19/2007 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
10/15/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE APPROVED COUPLING FOR PIPING
2. SHALL SECURE PIPING AT APPLIANCES AND DROP TO METER
3. SHALL PROVIDE BONDING FOR BUILDING GAS PIPING
4. SHALL PROVIDE APPROVED GAS SHUT OFF ON EXTERIOR AND AT BOTH APPLIANCES
5. COMPLETE GAS PIPING TO APPLIANCE SHUT OFF VALVES BOTH APPLIANCES REQUIRE SEPARATE VALVES.