Permit: T07OT01193

Parcel: 12218450B

Inspection Status: Approved

Inspection History: CERTIFICATE OF OCCUPANCY

Date Description Inspector Results Comments
06/25/2007 CERTIFICATE OF OCCUPANCY Approved FIRE APPROVED BY L THOMAS 6/25/07
06/22/2007 CERTIFICATE OF OCCUPANCY Not ready for Inspection IVRS - Inspection :*
NEED FIRE APPROVAL - OTHER CORRECTIONS COMPLETE
06/06/2007 CERTIFICATE OF OCCUPANCY Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. ACCESSIBLE PARKING SPACE MUST BE LOCATED ON FLAT AREA.
2. EXTERIOR HOSE BIBBS MUST HAVE ANTI-SIPHON DEVICES
3. IRRIGATION LINE REQUIRES BACKFLOW PROTECTION
4. EMERGENCY EGRESS LIGHTING REQUIRED
5. CAULK TOILET AT FLOOR
6. CAULK LAVATORY AT WALL
7. WALLS WITHIN 2' OF TOILET TO BE HARD, IMPERMEABLE SURFACE (4' HIGH)
8. DOOR HARDWARE FROM RESTROOM TO UNLOCK WHEN TURNED FROM INSIDE
9. ACCESSIBLE SIGNAGE REQUIRE FOR UNISEX
10. LEVER HANDLE HARDWARE REQUIRED ON ACCESSIBLE ROUTE.