Permit: T07OT01039

Parcel: 121060070


Addresses:

5601 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: SIGN SHOP

Date Description Inspector Results Comments
01/12/2009 SIGN SHOP Approved IVRS - Inspection :*
NEW WEATHERPROOF BOX WITH LOCKABLE SWITCH
07/29/2008 SIGN SHOP Partial Approval IVRS - Inspection :*
1. ISOLATE POWER TO SWITCHES AND INSTALL AS PER 600.6
2. EXPOSED CONDUCTORS IN A NON-WEATHERPROOF RACEWAY
06/18/2008 SIGN SHOP Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. REVISE PLANS - NO RACEWAY - PAN CHANNEL ON WALL
2. A SERVICE LIGHT IS NEEDED 210.70
3. A WALKWAY IS NEEDED - 600.21