Inspection History Details
Inspection Status: Denied
Inspection History: SIGN SHOP
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/30/2007 | SIGN SHOP | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. LABEL SIGN BREAKER 2. USE BREAKER LISTED FOR USE BY MANUFACTURE 3. SUPPORT M/C CABLE ABOVE CEILING AS PER CODE 4. FINISH #2 OF PREVIOUS INSPECTION 5. NO PLANS OR PERMIT ON SITE |
|
| 05/10/2007 | SIGN SHOP | Not ready for Inspection | IVRS - Inspection :* 1. FILL UNUSED OPENING IN BACK OF SIGN 2. A MARKING LABEL IS NEEDED 3. NO POWER TO SIGN |