Permit: T07OT01014

Parcel: 11307142B

Inspection Status: Approved

Inspection History: FIRE - FINAL

Permit Number - T07OT01014

Inspection Description - FIRE - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/04/2007 FIRE - FINAL Approved LOCK ON FRONT DOOR REMOVED
FRONT DOOR LABEL
FRONT DOOR LOCKES CORRECTED
REAR DOOR BOLT LOCK REMOVED
ALL APPROVED
05/03/2007 FIRE - FINAL Not ready for Inspection IFC 1008.1.8.3 LOCK & LATCHES - Double cylinder-keyed dead bolts are allowed on the front egress door, BUT you must label on the door in the inside the following: " THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". 1 inch high letters on a contrasting background.
IFC 1008.1.8.4 BOLT LOCKS - Are not permitted. Shall remove the bolt lock on the rear door.
IFC 1008.1.8.4 Hardware Height - Locks and other opening devices shall be installed 34 inches minimum & 48 inches maximum above floor finish. Shall remove the bottom-keyed dead bolt.