Inspection History Details
Inspection Status: Approved
Inspection History: SIGN SHOP
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/16/2007 | SIGN SHOP | Approved | IVRS - Inspection :* | |
| 05/01/2007 | SIGN SHOP | Partial Approval | IVRS - Inspection :* 1. GTO WEATHERPROOF SLEEVING TO BE FROM BOOT TO INSIDE OF PASS THROUGH AS PER MANUFACTURES INSTRUCTIONS. 2. SUPPORT FLEX CONDUIT OVER 4' LENGHTS AS PER CODE 3. PLEASE SUPPORT GROUNDING CONDUCTORS 4. PLEASE CLEAN TRASH UP FROM CEILING TILES. |
|
| 04/24/2007 | SIGN SHOP | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* WEST SIGN: 1. PROPERLY USE GROUND CLIPS 2. TIGHTEN GROUND WASHER CONNECTIONS - INSIDE & OUTSIDE 3. SLEEVE GTO FOR WEATHER/OUTDOOR USAGE 4. USE BOOTS LISTED FOR WEATHER/OUTDOOR USAGE 5. A MARKING LABEL IS NEEDED 6. A TERMINAL END IS NEEDED FOR STRANDED CONDUCTOR 7. SWITCH TO BE CAPABLE OF BEING LOCKED OUT 8. FINISH MAKE UP AND GROUND FAULT PATH 9. FINISH SOUTH SIGN |
|
| 04/19/2007 | SIGN SHOP | Not ready for Inspection | IVRS - Inspection :* 1. INSTALL PAN CHANNEL LETTERS TO INSPECT 2. DO NOT ENERGIZE SIGN UNTIL FINALED BY ELECTRICAL INSPECTOR DO NOT PUT LABELS ON SIGN (CITY STICKERS) DO INSTALL MARKING LABELS |