Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T07MH00087
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/25/2008 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
02/21/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED SMOKIES IN BEDROOM AND HALLWAY 2) RECEPTACLES AT KITCHEN NEEDS TO BE GFI 3) BATHROOM RECEPTACLES GFI AND COMPLETE ALL LIGHT FIXTURES 4) IDENTIFY ALL BREAKERS 5) RANGE RECEPTACLE NEEDS TO BE SINGLE TYPE 6) FINISH WIRING AT SERVICE PANEL 7) NEED TO FIX CONDUCTOR WIRE HANGING FROM CEILING AT FURNACE |