Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T07ME00817
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/17/2008 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
12/18/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - MARK UNIT DATA PLATE WITH PROPER HEAT STRIP AND FUSE ACCORDINGLY - PROVIDE AN OVERFLOW SENSOR ON SECONDARY DRAIN - EXTEND VENT IN CONDENSATE DRAIN ABOVE PAN IN FAN COIL - PROVIDE A PERMIT FOR NEW WATER HEATER & INCLUDE THE NEW SUB-PANEL & ELEC. CIRCUIT TO NEW WATER HEATER |