Permit: T07ME00781

Parcel: 110073220


Addresses:

2447 N SYCAMORE BL

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
12/05/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
11/30/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- REPAIR VENT CONNECTOR
- INSULATE SHEET METAL SLEEVE
- PROVIDE OVERFLOW SENSOR. REPLACE TRAP
- DO NOT TERMINATE CONDENSATE INTO A SEWER VENT
- EXTEND FURNACE VENT MIN. 3' ABOVE COMBUSTION AIR INTAKE
- REMOVE ABANDONED DUCT FROM ROOF
- REPAIR ELEC. DISCONNECT
- REMOVE WOODEN BLOCKS FROM CONDENSOR & SET ON APPROVED BASE