Permit: T07ME00705

Parcel: 121100700


Addresses:

4746 E SENECA ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
10/29/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
10/17/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- CONDENSATE CANNOT TERMINATE INTO A SEWER VENT
- TURN DISCONNECT 180 DEG. TO ALLOW ADEQUATE ACCESS
- PROVIDE A GFI SERVICE RECEPTACLE ON ROOF WITH WATERPROOF BUBBLE TYPE COVER.
- PROVIDE MIN. 2" R8 DUCT LINER IN EXPOSED DUCT ON ROOF
- INSULATE ALL DUCT IN THE ATTIC WITH R8 INSULATION W/VAPOR BARRIER
- FLEX DUCT TO BE MIN. R8
- PROVIDE ADEQUATE COMBUSTION AIR FOR WATER HEATER