Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2007 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* 125 PSI TEST IS OK |
|
| 10/11/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLEASE SCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME -- THERE WAS NO MESSAGE |
|
| 10/05/2007 | MECHANICAL - FINAL | Denied | SUCTION LINE LEAKING IN FAN COIL COMPARTMENT LINE SET MAY NEED A P-TRAP TO GET THE OIL BACK UP TO THE COMPRESSOR. REPAIR LEAK & PROVIDE A MIN. 100 LB PRESSURE TEST ON ENTIRE LINE SET. |
|
| 10/04/2007 | MECHANICAL - FINAL | Cancelled | IVRS - RI canceled | |
| 09/27/2007 | MECHANICAL - FINAL | Denied | - PROVIDE A TRAP ON CONDENSATE DRAIN LINES AS PER INSTALL INSTRUCTIONS. PROVIDE A SECONDARY OVERFLOW SENSOR - SUPPORT REFER LINES UP OFF OF CEILING - DO A BETTER JOB SEALING AROUND REFER LINE PENETRATING THE ROOF - INSULATE ALL OF THE SUCTION LINE NOT ABOVE DRAIN PAN |
|
| 09/25/2007 | MECHANICAL - FINAL | Cancelled | IVRS - RI canceled |