Permit: T07ME00599

Parcel: 135102970


Addresses:

7310 E 32ND ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
09/12/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
09/06/2007 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
USE THE PROPER FITTING LISTED FOR USE ON TOP OF A PANEL & PROVIDE A LOCK NUT ON THE INSIDE
08/29/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- PROVIDE A SEDIMENT TRAP ON GAS LINE AT FURNACE
- PROVIDE A HOSE CLAMP ON CONDENSATE PUMP
- PROVIDE AN OVERFLOW SENSOR ON SECONDARY DRAIN
- INSULATE SHEETMETAL DUCT ABOVE FURNACE
- PROVIDE A WATERPROOF FITTING ON TOP OF CIRCUIT PANEL
- CONNECT PUMP DRAIN TO PVC WITH A FITTING
- DO NOT USE WHITE WIRE IN DISCONNECT
- EXTEND FURNACE VENT MIN. 3' ABOVE COMBUSTION AIR INTAKE
08/23/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
PLEASE SCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME.