Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T07ME00556
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/31/2007 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE |
|
| 08/09/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* CONDENSATE DRAINS DO NOT HAVE ADEQUATE SLOPE. PROVIDE MIN. 1/8" PER FT. SLOPE DIVERT WATER AWAY FROM HOUSE SECURE DRAIN LINE TO WALL SUPPORT HORIZONTAL SECTIONS EVERY 4' (CLAMP) USE ONLY A SIEMENS BREAKER IN CIRCUIT PANEL NON-METALLIC CONDUIT MUST BE MIN. 18" BURIAL DEPTH PLEASE UNCOVER |