Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T07ME00546
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/18/2007 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
08/10/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF FURNACE VENT CONNECTOR 2) CLEAN UP JAGGED CUT EDGES ON COMBUSTION AIR DUCT 3) CONDENSATE CANNOT TERMINATE INTO A SEWER VENT 4) BLOCK AND CLAMP 3/8" DRAIN LINE EVERY 6' 5) TERMINATE WITHIN 6" OF THE GROUND 6) SECURE REFER LINES TO WALL 7) SEAL AROUND REFER LINE PENETRATION THRU BIRD BLOCK |