Permit: T07ME00539

Parcel: 130190600


Addresses:

4642 E CALLE AURORA

Inspection Status: Denied

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
08/09/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- PROVIDE THE PROPER FITTING TO CONNECT PLASTIC CONDUIT TO ELEC. DISCONNECT
- RED WIRE IN DISCONNECT APPEARS TO BE SHORTED OUT
- WIRE HAS A NICK IN THE COATING
- DISCONNECT HAS TO BE SHAKEN SIDE TO SIDE TO GET A PROPER CONNECTION
08/06/2007 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
1. SUPPORT NEW GAS PIPING IN FURNACE CLOSET AND PROVIDE MINIMUM TEST ON THIS PIPING
2. PROVIDE BLOCKING SUPPORT FOR POWER SUPPLY CONDUIT WITH APP. CONDUIT TO DISCONNECT ON ROOF WITH APPROVED WEATHER PROOF TERMINATION AT BOX.
08/02/2007 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
PROVIDE ACCESS TO ROOF