Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07ME00444

Parcel: 123130600


Addresses:

2136 N EUCLID AV


Inspection Status: Denied

Inspection History: MECHANICAL - FINAL

Permit Number - T07ME00444

Inspection Description - MECHANICAL - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
07/05/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. 3/8" I.D X 36" GAS FLEX NOT ADEQUATE FOR 100,000 BTU
FURNACE
2. PAINT EXPOSED PVC W/LATEX PAINT
3. PROVIDE MIN. R8 DUCT INSULATION IN EXPOSED DUCT ON ROOF
4. PROVIDE A BUSHING IN THE ELEC. DISCONNET
PROVIDE FUSES
5. PROVIDE A NEW ELEC. CIRCUITS TO THE DISCONNECT & PROVIDE A PERMIT FOR THE NEW CIRCUIT. ALSO, PROVIDE A GFI SERVICE RECEPTACLE ON THE ROOF.
6. SUPPORT & SECURE LOW VOLTAGE CONDUIT