Inspection History Details
Inspection Status: Denied
Inspection History: MECHANICAL - FINAL
Permit Number - T07ME00444
Inspection Description - MECHANICAL - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/05/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. 3/8" I.D X 36" GAS FLEX NOT ADEQUATE FOR 100,000 BTU FURNACE 2. PAINT EXPOSED PVC W/LATEX PAINT 3. PROVIDE MIN. R8 DUCT INSULATION IN EXPOSED DUCT ON ROOF 4. PROVIDE A BUSHING IN THE ELEC. DISCONNET PROVIDE FUSES 5. PROVIDE A NEW ELEC. CIRCUITS TO THE DISCONNECT & PROVIDE A PERMIT FOR THE NEW CIRCUIT. ALSO, PROVIDE A GFI SERVICE RECEPTACLE ON THE ROOF. 6. SUPPORT & SECURE LOW VOLTAGE CONDUIT |