Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/03/2007 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 07/30/2007 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 07/11/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* STILL NO WATER HEATER PERMIT ON FILE EVERYTHING ELSE IS OK |
|
| 06/28/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. STILL NO WATER HEATER PERMIT 2. FURNACE STILL HAS 3/8" I.D FLEX 3. PROVIDE INSTALL INSTRUCTIONS FOR CSST GAS PIPE 4. STILL NO GFI SERVICE RECEPTACLE PAY A REINSPECTION FEE PRIOR TO NEXT INSPECTION |
|
| 06/19/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. BLOCK & CLAMP PVC EVERY 4' & EXTEND TO WITHIN 6" OF THE GROUND WITH AN ELBOW & NIPPLE AT BOTTOM. 2. SUPPORT THE GAS LINE ON ROOF 3/8" I.D GAS FLEX NOT ADEQUATE FOR 120,000 BTU REDO THE GAS FITTINGS ON CSST AS PER INSTALL INSTRUCTIONS. 3. DO NOT USE WHITE WIRE 4. PROVIDE A GFI RECEPTACLE ON ROOF PROVIDE A PERMIT FOR NEW WATER HEATER AND YOU'LL NEED A PETITION OF APPEAL TO USE THE ALTERNATE METHOD OF TERMINATING THE T&P RELIEF VALVE. DRAIN CANNOT RUN UPHILL. |
|
| 06/13/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 12:32 AM NO ACCESS, SHALL PROVIDE LADDER AND HAVE ACCESS |