Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2007 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE |
|
| 07/06/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* GAS FLEX STILL NOT ADEQUATE CONDENSATE STILL NOT SLOPED 1/8" PER FT |
|
| 05/15/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. 3/8" I.D X 36" GAS FLEX CONNECTOR NOT ADEQUATE FOR 120,000 BTU. 2. BLOCK & CLAMP CONDENSATE DRAIN EVERY 4' AND PAINT WITH LATEX PAINT & PROVIDE MIN. 1/8" PER FT. SLOPE. SECURE TO THE SIDE OF THE HOUSE. TERMINATE WITHIN 6" OF THE GROUND WITH AN ELBOW & NIPPLE. DIVERT THE WATER AWAY FROM THE HOUSE. 3. PROVIDE A GFI SERVICE RECEPTACLE ON THE ROOF WITH A WATERPROOF COVER AS PER N.E.C 4. NEED TO SEE CIRCUIT BREAKER. |