Permit: T07ME00301

Parcel: 128021330


Addresses:

6012 E 16TH PL

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
05/14/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
05/03/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE AN OVERFLOW SENSOR OR SECONDARY DRAIN OUTLET.
2. PROVIDE SEDIMENT TRAPS AT FURNACE & WATER HEATER
3. PROVIDE A PERMIT FOR NEW WATER HEATER & PROVIDE A PETITION OF APPEAL FOR ALTERNATE METHOD OF TERMINATING T&P RELIEF DRAIN.
4. T&P CANNOT RUN UPHILL
5. YOU CANNOT HAVE COPPER FLEX ON A T&P DRAIN.
6. SLOPE THE VENT CONNECTOR MIN. 1/4" PER FT & PROVIDE SCREWS.
7. PROVIDE PROPER DESCRIPTION OF WORK PERFORMED
8. A SPLIT SYSTEM WAS NOT REPLACED
9. CONDENSATE CANNOT TERMINATE INTO A SEWER VENT
10. SUPPORT COPPER DRAIN EVERY 6'