Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
04/12/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
04/03/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE A SECONDARY DRAIN TO A CONSPICUOUS LOCATION OR PROVIDE AN OVERFLOW SENSOR.
2. PROVIDE HOSE CLAMPS ON PUMP DRAIN CONNECTIONS
3. PROVIDE A ROMEX CONNECTOR WHERE POWER CORD CONNECTS TO FURNACE.
4. GAS FLEX CONNECTOR NOT ADEQUATE FOR 100,000 BTU FURNACE
5. INSULATE SHEET METAL DUCT ON TOP OF EVAP. COIL
6. DO NOT USE WHITE WIRE TO POWER CONDENSOR
TAPE BOTH ENDS WITH BLACK TAPE.
7. 60 AMP CIRCUIT REQUIRES #6 WIRE --50 AMP YOU COULD USE #8