Permit: T07ME00114

Parcel: 134232480


Addresses:

6333 E SCARLETT ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
03/02/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
02/28/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. HUMIDIFIER CONTROL WIRING TO BE PROTECTED FROM WEATHER & VERMIN
2. CONDENSATE DRAIN TO BE ON SUPPORTS ON ROOF AT 4' INTERVALS
3. PROVIDE CORRECT PERM CAP OR TRANSITION FITTING FOR VENT SYSTEM FROM WATER HEATER TO DOUBLE WALL VENT AT CEILING ELEVATION.
4. PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT PIPING AND PROVIDE APPROVED SINGLE WALL VENT PIPING FROM WATER HEATER.