Permit: T07ME00083

Parcel: 124190010


Addresses:

1002 S CAMPBELL AV

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
01/07/2009 MECHANICAL - FINAL Approved IVRS - Inspection :*
01/06/2009 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
FAU UNIT FLUE PIPING RUN BACKWARDS
02/01/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
WATER HEATER FLUE PIPE NEEDS TO BE PROPERLY STRAPPED AND SUPPORTED. PROVIDE 1" CLEARANCE TO COMBUSTIBLES (SHEETROCK, WOOD) ON B-VENT.

PROVIDE SECONDARY DRAIN ON EVAP. COIL

EXPOSED EXTERIOR PVC PIPING IS TO BE PAINTED WITH LATEX CONDENSATE PIPING CANNOT TERMINATE ON A HARD SURFACE ALL PVC JOINTS MUST BE PRIMED PRIOR TO GLUE.
02/26/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTES ABOVE & COMPLY WITH THEM. FAILURE TO DO SO WILL RESULT IN REFEE
02/21/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE CORRECT FUSES FOR RATING PLATE AT OUTDOOR SECTION.
2. SHALL PROVIDE SEPARATE DRAIN FOR SECONDARY DRAIN PAN.
3. CONDENSATE DRAIN TO BE SEPARATE FROM PAN DRAIN AND HAVE CORRECT FALL.
4. PROVIDE INSTALLATION INSTRUCTION MANUAL FOR FURNACE TO VERIFY HORIZONTAL INSTALL & POSSIBLE HEAT SHIELDING REQUIREMENTS.