Permit: T07ME00048

Parcel: 133352130


Addresses:

8925 E 5TH ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
02/12/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
02/08/2007 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1) RE-INSULATE SHEET METAL WITH INSULATION THAT HAS A VAPOR BARRIER-COVER ALL BARE METAL
2) CONNECT OVERFLOW SENSOR ON PUMP
3) PLASTIC HOSE IS FLATTENED AND KINKED
4) LEFT GAS CARD
02/01/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INCREASE VENT CONNECTOR TO 4" AT FURNACE OUTLET
2) PROVIDE A TRAP ON CONDENSATE DRAIN LINE. PLASTIC MUST BE 6" AWAY FROM FURNACE VENT
3) INSULATE ALL EXPOSED SHEET METAL ABOVE EVAP COIL
4) PROVIDE A 3/8" DRAIN FROM CONDENSATE PUMP. USE HOSE CLAMPS AT CONNECTION TO PLASTIC HOSE
5) CONDENSATE CANNOT TERMINATE INTO A SEWER VENT