Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/12/2007 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE |
|
| 02/08/2007 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1) RE-INSULATE SHEET METAL WITH INSULATION THAT HAS A VAPOR BARRIER-COVER ALL BARE METAL 2) CONNECT OVERFLOW SENSOR ON PUMP 3) PLASTIC HOSE IS FLATTENED AND KINKED 4) LEFT GAS CARD |
|
| 02/01/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INCREASE VENT CONNECTOR TO 4" AT FURNACE OUTLET 2) PROVIDE A TRAP ON CONDENSATE DRAIN LINE. PLASTIC MUST BE 6" AWAY FROM FURNACE VENT 3) INSULATE ALL EXPOSED SHEET METAL ABOVE EVAP COIL 4) PROVIDE A 3/8" DRAIN FROM CONDENSATE PUMP. USE HOSE CLAMPS AT CONNECTION TO PLASTIC HOSE 5) CONDENSATE CANNOT TERMINATE INTO A SEWER VENT |