Inspection Status: Approved
Inspection History: INSP - FULL
Case Number - T07FR02511
Inspection Description - INSP - FULL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2008 | INSP - FULL | Approved | ||
| 01/08/2008 | INSP - FULL | Approved | ||
| 12/10/2007 | INSP - FULL | Correction Required | The Tucson Fire Department has conducted a fire safety inspection at the above stated business . Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code (with modifications). ___1. PROBLEM: Extension cord being used in front office for fax/printer. TFC REFERENCE: 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. REQUIRED CORRECTION: Plug printer/fax directly into electrical outlet or use power strip. ___2. PROBLEM: Emergency light in break room not working. TFC REFERENCE: 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. REQUIRED CORRECTION: Emergency back up lighting shall function properly. ___3. PROBLEM: Sprinkler head in side office missing escutcheon. TFC REFERENCE: 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. REQUIRED CORRECTION: Replace missing escutcheon plate on sprinkler. ___4. PROBLEM: Fire extinguisher found under sink without service tag. TFC REFERENCE: 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. AND: 906.7 Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer’s installation instructions. REQUIRED CORRECTION: Fire extinguishers, if present, shall be serviced annually and display a tag indicating last service date. Also portable fire extinguisher shall be mounted on a bracket as per code spec. The Tucson Fire Department is committed to the protection of your property and your life safety. Your help as a business owner and as a citizen is greatly appreciated. Property Representative Signature: _________________________. Fire Inspector Signature: _________________________(791-4502). Reinspection Date: _01__/_08__/_08__ or later. _X__Approved ___Not Approved |