Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2007 | INSP - FULL | Approved | ||
| 12/04/2007 | INSP - FULL | Correction Required | The Tucson Fire Department has conducted a fire safety inspection at the above stated business . Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code (with modifications). ___1. PROBLEM: Power strip not secured. TFC REFERENCE: 605.4.3 Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. REQUIRED CORRECTION: Secure power strip so strip does not hang on plugs. ___2. PROBLEM: Thumb turn latch on South exit with panic hardware. TFC REFERENCE: Section 1028.6 Panic hardware. Where panic and fire exit hardware is installed, the panic or fire exit hardware shall be the only locking device on the door ... REQUIRED CORRECTION: Remove thumb turn lock from door with panic hardware. Property Representative Signature:_________________________ Fire Inspector Signature:_________________________ Reinspection Date:___/___/___ _X__Approved ___Not Approved |