Case: T07FR02260

Parcel: 141185830

Inspection Status: Approved

Inspection History: INSP - FULL

Date Description Inspector Results Comments
11/08/2007 INSP - FULL Approved
11/07/2007 INSP - FULL Correction Required PROBLEM: Extension cord on T.V. in "childrens room".
CODE REF: 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords
and flexible cords shall not be affixed to structures, extended
through walls, ceilings or floors, or under doors or floor coverings...
REQUIRED CORRECTION: Plug T.V. directly into outlet or into power strip with GFI.

PROBLEM: Storage around electrical panel.
CODE REF: 605.3Working space and clearance. A working space of not less than 30 inches (762 mm) in width, 36 inches (914 mm) in
depth and 78 inches (1981 mm) in height shall be provided in
front of electrical service equipment. Where the electrical service
equipment is wider than 30 inches (762 mm), the working
space shall not be less than the width of the equipment. No storage
of any materials shall be located within the designated working space.
REQUIRED CORRECTION: Keep electrical panel clear of storage.


Representative Signature:_________________________

Inspector Signature: _________________________

Reinspection date: 11/21/07 or later.


Met with rep. to have report signed. Has already resolved code violations. Inspection approved.