Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/19/2007 | INSP - FULL | Approved | Upon reinspection all violations corrected. | |
| 11/05/2007 | INSP - FULL | Correction Required | FIRE INSPECTION REPORT A/P/D: T07FR02250 November 5/2007 Long Realty ATTN: Malissa Brown 10222 E Rita Rd. Tucson, AZ. 85747 Mrs. Brown, The Tucson Fire Department has conducted a fire safety inspection at the above stated business on November 5, 2007. Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code (with modifications). A Re-inspection will be performed on or about November 19, 2007 Notice of Violations: _____ 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. · Fire extinguisher shall be serviced annually (last inspection 2003). _____ 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, back-up power shall be supplied. Provide back up power supply for all required exit illumination: · Exit sign and emergency backup lighting in the break room shall operate _____ 901.4 Installation. Fire protection systems shall be maintained in accordance with the original installation standards for that system. Systems shall be extended, altered, or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. · Replace missing escheson in the ladies bathroom. · Re-adjust sprinkler head in the ladies bathroom so that the coverage is not hampered. · Extend sprinkler system to maintain coverage in the "West Wing" bathroom -Currently there is no cover in the room The Tucson Fire Department is committed to the protection of your property. Your help as a business owner and as a citizen is greatly appreciated. __________________________________________________ Property owner or Property Representative Signature _________________________________ Abatement Date __________________________ Captain Signature Sincerely, Jimmy R. Davis, Jr Fire Inspector Tucson Fire Department |