Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - LIFE SAFETY
Case Number - T07FR02186
Inspection Description - INSP - LIFE SAFETY
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2007 | INSP - LIFE SAFETY | Approved | ||
| 10/24/2007 | INSP - LIFE SAFETY | Correction Required | 403.2 Temporary haunted house shall be maintained in accordance with the Amusement Buildings and Temporary Permits for Haunted Houses handout provided. Building shall not be occupied by the public before approval. Open flame or flammable or combustible liquids are prohibited within occupancy. Guides shall be provided for groups of occupants. Groups of occupants shall be limited to 20 persons. Guides shall have flashlights and be in communication with attendant located at house light control. Exit signs shall be installed at east and west exits. Emergency backup shall be provided for lighting in case of power failure. Directional path markings shall be provided on the floor to indicate exits direction. |