Case: T07FR02153

Parcel: 13314236C


Addresses:

1105 N KOLB RD


Inspection Status: Approved

Inspection History: INSP - SELF INSPECTION PROGRAM

Case Number - T07FR02153

Inspection Description - INSP - SELF INSPECTION PROGRAM

Inspection Status - Approved

Date Description Inspector Results Comments
01/08/2008 INSP - SELF INSPECTION PROGRAM Approved abated
12/13/2007 INSP - SELF INSPECTION PROGRAM Correction Required nothing done: Pre-citation letter sent, see below:

PRE-CITATION LETTER
A/P/D: T07FR02153


12/13/07


Catalina Recruiting Station
ATTN: Michael Fredgeon
1105 N. Kolb Rd. #110
Tucson, AZ. 857

RE: Fire Inspection

Dear Sir,

The Tucson Fire Department has conducted a fire safety inspections at the above stated business on November 20, 2007. At that time a notice was issued indicating the corrections required to provide compliance with the applicable codes, regulations and ordinances. Subsequent re-inspections were also conducted on December 4 and December 12, 2007. We were unable to gain voluntary compliance.

Compliance is required by the 2006 International Fire Code w/Modification

901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective...

906.2 General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.


This letter is to inform you that if the above stated necessary corrections have not been completed by December 27, 2007 a citation will be issued which will require an appearance by you in court with a probable fine. This letter is written as a courtesy to you in order to avoid future litigation.


Sincerely,


Jimmy R. Davis, Jr.
Fire Inspector
Tucson Fire Department
12/06/2007 INSP - SELF INSPECTION PROGRAM Approved Re-inspection Dec. 5, 2007 Item #5 still needs abatement.
Reinspectoin scheduled for December12, 2007
11/19/2007 INSP - SELF INSPECTION PROGRAM Correction Required Re-inspection scheduled for Dec. 4, 2007

item #4
10/22/2007 INSP - SELF INSPECTION PROGRAM Correction Required 1. IFC 505.1: Is the address clearly visible from the street? Y

2. IFC 901.6: Is there an extinguisher (75 feet)? Y

3. IFC 901.7: Is the fire extinguisher mounted properly? Y

4. IFC 901.6: ...Serviced within the last year? N

5. IFC 1008.1.8.3: "Door to Remain Unlocked" sign posted? (no answer)

6. IFC 10011.1: Are exits identified with EXIT signs? Y

7. IFC 1027.2: Is the exit clear of obstructions? Y

8. IFC 605.3: Proper electrical panels clearance? N

9. IFC 315.2.1: Stored materials two feet below the ceiling? Y

10. IFC 1026.3: Does emergency lighting work? Y

11. IFC 605.5: Extension cords used only temporarily? Y

12. IFC 605.1: Outlets have no more than two items plugged in? Y

13. IFC 605.6: Are all switches/outlets equipped with covers? Y

14. IFC 3404.3.4.2 #2: Less than 10 gal of flammable liquid? Y

15. IFC 901.6: Sprinkler system been tested within 12 mos? N

16. IFC 901.6: Fire alarm system been tested within 12 mos? Y

17. IFC 305.1: Heat-producing appliances clear of combustibles? NA

PERSON NAME: Michael Fredgren
BUSINESS NAME: Catalina Recruiting Station
PHONE: 296-0264