Inspection History Details
Inspection Status: Approved
Inspection History: VIOL - MEANS OF EGRESS
Case Number - T07FR02083
Inspection Description - VIOL - MEANS OF EGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/09/2007 | VIOL - MEANS OF EGRESS | Approved | All exiting issues abated. | |
10/17/2007 | VIOL - MEANS OF EGRESS | Violation | Front Doors: IFC2006 (with modifications) / 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 1. Places of detention or restraint. 2. In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F,Mand S, and in places of religious worship, the main exterior door or doors are permitted to be equipped with key-operated locking devices from the egress side provided: 2.1. The locking device is readily distinguishable as locked, 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background, 2.3. The use of the key-operated locking device is revokable by the fire code official for due cause. ______ Place sign over all three front doors. |
|
10/17/2007 | VIOL - MEANS OF EGRESS | Violation | Exit signs not lit: IFC2006 [with modifications / 1026.3 Exit sign illumination. Exit signs shall be internally or externally illuminated. _____Fix light in exit signs. |
|
10/17/2007 | VIOL - MEANS OF EGRESS | Violation | Double keyed locks on doors: IFC2006 [TFC with modifications] / 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ______ Remove keyed dead bolts. [Use one Thumb turn type on each front door] |
|
10/17/2007 | VIOL - MEANS OF EGRESS | Violation | Sign needed over each front door: IFC2006 [TFC with modifications] / 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 1. Places of detention or restraint. 2. In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F,Mand S, and in places of religious worship, the main exterior door or doors are permitted to be equipped with key-operated locking devices from the egress side provided: 2.1. The locking device is readily distinguishable as locked, 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background, 2.3. The use of the key-operated locking device is revokable by the fire code official for due cause. ______ Place sign over front doors [3]. |