Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T07FR01686

Parcel: 12613018A


Addresses:

4518 E BROADWAY BL


Inspection Status: Correction Required

Inspection History: INSP - SELF INSPECTION PROGRAM

Case Number - T07FR01686

Inspection Description - INSP - SELF INSPECTION PROGRAM

Inspection Status - Correction Required

Date Description Inspector Results Comments
08/28/2007 INSP - SELF INSPECTION PROGRAM Correction Required SELF INSPECTION PROGRAM

1. IFC 505.1: Is the address of your property (Building) clearly visible from the street? Y

2. IFC 901. 6: Is there at least 1 fire extinguisher within 75 feet travel distance from anywhere in the business? Y

3. IFC 901.7: Is the fire extinguisher mounted in a visible and accessible location? Y

4. IFC 901.6: Have the fire extinguisher(s) been serviced within the last year? Y

5. IFC 1008.1.8.3: 1If the main exit door has a key lock, does it have a sign that reads, "This Door to Remain Unlocked While The Building Is Occupied"? Y

6. IFC 10011.1: Are exits identified with EXIT signs? Y

7. IFC 1027.2: Is the exit(s) clear of obstructions so during an emergency, people can exit quickly and safely? Y

8. IFC 605.3: Do the electrical panels have a 36-inch clearance in front and 30 inches in width for easy access? Y

9. IFC 315.2.1: Are all stored materials stacked so they are at least two feet below the ceiling? Y

10. IFC 1026.3: If you have emergency lighting, does it work? NA

11. IFC 605.5: Are extension cords used only for temporary wiring? Y

12. IFC 605.1: Do the electrical receptacles (outlets) have no more than two items plugged into them? Y

13. IFC 605.6: Are all electrical boxes, switches and outlets equipped with covers to protect the user from shock? Y

14. IFC 3404.3.4.2 #2: Do you have less than 10 gallons of flammable or combustible liquid being stored on site? Y

15. IFC 901.6: If you have a sprinkler system in your building, has it been tested and serviced within the past 12 months? NA

16. IFC 901. 6: If your building has a fire alarm system, has the system been tested and serviced within the past 12 months? Y

17. IFC 305.1: Is the area around the furnace, water heater or any other heat producing appliance clear of combustible materials? N

BUSINESS NAME: JACKSON HEWITT TAX SERVICE
PERSON COMPLETING THIS FORM: ANA MCQUIRK
PHONE: 320-1040
DATE COMPLETED: 8/20/07
08/28/2007 INSP - SELF INSPECTION PROGRAM Approved