Case: T07FR01551

Parcel: 133170600


Addresses:

410 N WILMOT RD


Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T07FR01551

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
12/14/2007 VIOL - MEANS OF EGRESS Approved
08/13/2007 VIOL - MEANS OF EGRESS Violation Misleading Exit sign:
TFC2006/ 1028.4 Exit signs. Exit signs shall be installed and maintained in accordance with section 1011. Decorations, furnishings,equipment, or adjacent signage that impairs the visibility of exit signs, creates confusion or prevents identification of the exit shall not be allowed.

______ Have a "blank" side installed on the hallway exit sign, so that the sign only directs person to outside, not to the dead end side.
08/10/2007 VIOL - MEANS OF EGRESS Violation Emergency lighting:

TFC2006/ 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: [Where currently located]

______Fix all inoperative emergency lights.
08/10/2007 VIOL - MEANS OF EGRESS Violation Panic Hardware:

TFC2006 / 1028.8 [Tucson Fire Code Modifications] Where panic hardware and fire exit hardware is installed, whether required or not, panic or fire exit hardware shall be the only locking device on the door except where otherwise permitted in this code.

______Remove key lock on patio door.