Inspection History Details
Inspection Status: Approved
Inspection History: VIOL - BUILDING SVCS & SYSTEMS
Case Number - T07FR01551
Inspection Description - VIOL - BUILDING SVCS & SYSTEMS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/09/2008 | VIOL - BUILDING SVCS & SYSTEMS | Approved | ||
12/14/2007 | VIOL - BUILDING SVCS & SYSTEMS | Partial Approval | Extension cord by TV [kit] | |
08/10/2007 | VIOL - BUILDING SVCS & SYSTEMS | Violation | Extension cords: TFC2006/ 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. _____Replace with approved power strip. |
|
08/10/2007 | VIOL - BUILDING SVCS & SYSTEMS | Violation | Wires bad on side-by-side unit: TFC2006/ 605.1 Abatement of electrical hazards. Identified electrical hazards shall be abated. ______ Replace wires in an approved manor. [and check all other equipment for electrical hazards] |
|
08/10/2007 | VIOL - BUILDING SVCS & SYSTEMS | Violation | Multiplug adapters: TFC2006/ 605.4 Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited. ______Remove noncomplying devices. |