Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
09/11/2007 VIOL - MEANS OF EGRESS Approved All o.k. 9/6.
08/07/2007 VIOL - MEANS OF EGRESS Correction Required -Exit signs out of service in emergency mode.
(Computer room)
(Chapter room) 2006 IFC-1011.5.3
***Repair exit signs to illuminate during power interruptions.
08/07/2007 VIOL - MEANS OF EGRESS Correction Required -Exit door difficult to open, should open freely.
(Chapter room) 2006 IFC 1008.1.9
***Repair door to open freely, with less than 15lbs. unlatching force.
08/07/2007 VIOL - MEANS OF EGRESS Correction Required -Emergency lighting out of service.
(Chapter room) 2006 IFC-1027.5
***Repair emergency lighting.