Case: T07FR01438

Parcel: 134234170


Addresses:

6436 E BROADWAY BL

Inspection Status: Compliance

Inspection History: INSP - SELF INSPECTION PROGRAM

Date Description Inspector Results Comments
08/01/2007 INSP - SELF INSPECTION PROGRAM Compliance
07/31/2007 INSP - SELF INSPECTION PROGRAM Continued 1. YES IFC 505.1: Is the address of your property (Building) clearly visible from the street?

2. YES IFC 901. 6: Is there at least 1 fire extinguisher within 75 feet travel distance from anywhere in the business?

3. YES IFC 901.7: Is the fire extinguisher mounted in a visible and accessible location?

4. YES IFC 901.6: Have the fire extinguisher(s) been serviced within the last year?

5. NO IFC 1008.1.8.3: 1If the main exit door has a key lock, does it have a sign that reads, "This Door to Remain Unlocked While The Building Is Occupied"?

6. NO IFC 10011.1: Are exits identified with EXIT signs?

7. YES IFC 1027.2: Is the exit(s) clear of obstructions so during an emergency, people can exit quickly and safely?

8. YES IFC 605.3: Do the electrical panels have a 36-inch clearance in front and 30 inches in width for easy access?

9. YES IFC 315.2.1: Are all stored materials stacked so they are at least two feet below the ceiling?

10. NA IFC 1026.3: If you have emergency lighting, does it work?

11. YES IFC 605.5: Are extension cords used only for temporary wiring?

12. YES IFC 605.1: Do the electrical receptacles (outlets) have no more than two items plugged into them?

13. YES IFC 605.6: Are all electrical boxes, switches and outlets equipped with covers to protect the user from shock?

14. YES IFC 3404.3.4.2 #2: Do you have less than 10 gallons of flammable or combustible liquid being stored on site?

15. NA IFC 901.6: If you have a sprinkler system in your building, has it been tested and serviced within the past 12 months?

16. NA IFC 901. 6: If your building has a fire alarm system, has the system been tested and serviced within the past 12 months?

17. YES IFC 305.1: Is the area around the furnace, water heater or any other heat producing appliance clear of combustible materials?


NAME OF PERSON COMPLETING THIS FORM: Deborah Jones
BUSINESS NAME: Roy Drachman Realty
PHONE:
07/24/2007 INSP - SELF INSPECTION PROGRAM Continued SIP delivered