Case: T07FR01160

Parcel: 122070170


Addresses:

4405 E PIMA ST

Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
07/16/2007 VIOL - MEANS OF EGRESS Approved
06/19/2007 VIOL - MEANS OF EGRESS Violation Bolt lock:
TFC 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted.

______Remove bolt lock.
06/19/2007 VIOL - MEANS OF EGRESS Violation Double keyed lock on door:
1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.

______ Remove Keyed dead bolt.
06/19/2007 VIOL - MEANS OF EGRESS Violation Replace panic hardware:
1008.1.9 Panic and fire exit hardware. Where panic and fire exit hardware is installed, it shall comply with the following:
1. The actuating portion of the releasing device shall extend at least one-half of the door leaf width.
2. A maximum unlatching force of 15 pounds (67 N).
Each door in a means of egress from an occupancy of Group A or E having an occupant load of 100 or more and any occupancy of Group H-1, H-2, H-3 or H-5 shall not be provided with a latch or lock unless it is panic hardware or fire exit hardware.

______ Replace panic hardware, where missing.


TFC 1027.6 [ammendment] Panic Hardware:
Where panic hardware and fire exit hardware is installed, whether required or not, panic or fire exit hardware shall be the only locking device on the door except where otherwise permitted in this code.

__xx___Remove bolt constraint [above].
06/19/2007 VIOL - MEANS OF EGRESS Violation Exit sign not lit:
TFC 1026.3 Exit sign illumination. Exit signs shall be internally or externally illuminated.

_____Fix light in exit sign.