Inspection Status: Approved
Inspection History: VIOL - FLAMMABLE LIQUIDS
| Date |
Description |
Inspector |
Results |
Comments |
| 07/19/2007 |
VIOL - FLAMMABLE LIQUIDS |
|
Approved |
All violations have been corrected. |
| 05/04/2007 |
VIOL - FLAMMABLE LIQUIDS |
|
Violation |
IFC 3405.3.6.2.7 Installation. Machines shall be installed in accordance with their listings. Parts machine will be plugged into an outlet that contains a GFI per manufacturers instructions. |
| 05/04/2007 |
VIOL - FLAMMABLE LIQUIDS |
|
Violation |
IFC 3405.3.6.2 Listed and approved machines. Parts cleaning and degreasing conducted in listed and approved machines in ccordance with Section 3405.3.6.1 shall be in accordance with Sections 3405.3.6.2.1 through 3405.3.6.2.7. Discontinue use of your parts washer until you replace the fusable link in automatic closing lid. This link is part of the listed 'approved' machine and must be in place in the event of an ignition of vapors to prevent flame spread. |
| 05/04/2007 |
VIOL - FLAMMABLE LIQUIDS |
|
Violation |
IFC 3404.3.3.3 Storage of any liquids, including stock for sale, shall not be stored near y the route of egress. Move gasoline can, drum containing waste oil and oil cans from storage near exit in maintainence room. |