Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T07FR00875

Parcel: 133231430


Addresses:

7823 E BROADWAY BL


Inspection Status: Correction Required

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T07FR00875

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Correction Required

Date Description Inspector Results Comments
05/29/2007 VIOL - MEANS OF EGRESS Correction Required TFC 1008.1 - Doors. Means of egress doors shall meet the requirements of this section... Doors provided for egress purposes in numbers greater than required by this code shall meet the requirements of this section

Double keyed lock on door:
TFC 1008.1.8 - Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.

TFC 1008.1.8.3 - Locks and latches shall be permitted to prevent operation of doors where any of the following exists:
2. In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in churches, the main exterior door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:
2.1. The locking device is readily distinguishable as locked,
2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating:
THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch high on a contrasting background,
2.3. The use of the key-operated locking device is revocable by the fire code official for due cause.

TFC 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted.

_____ The front door shall comply with the Tucson Fire Code.

_____ The rear door shall comply with the Tucson Fire Code.
05/29/2007 VIOL - MEANS OF EGRESS Correction Required TFC 1026.3 - Exit sign illumination. Exit signs shall be internally or externally illuminated.

_____ Fix light in exit sign.