Case: T07FR00818

Parcel: 128010420


Addresses:

1120 S WILMOT RD


Inspection Status: Violation

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T07FR00818

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Violation

Date Description Inspector Results Comments
04/27/2007 VIOL - MEANS OF EGRESS Violation IFC 1008.1.8.4 Manually operated flush bolts or surface bolts are not permitted. Remove surface bolts from all exit doors.(Rear exit doors ( West) and Front main exit door were noted.)
04/27/2007 VIOL - MEANS OF EGRESS Violation IFC 1008.1.9 Each door in a means of egress from an occupancy of Group A or E having an occupant load of 100 or more and any occupancy of Group H-1, H-2, H-3 or H-5 shall not be provided with a latch or lock unless it is panic hardware or fire exit hardware. Place panic hardware on all required exits with latches or locks.
04/27/2007 VIOL - MEANS OF EGRESS Violation IFC 1011.1 Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Place an illuminated exit sign over NW exit ( old Vip room)
04/27/2007 VIOL - MEANS OF EGRESS Violation IFC 1004.3 Posting of occupant load. Every room or space that is
an assembly occupancy shall have the occupant load of the room
or space posted in a conspicuous place. Post your occupant load in every room of assembly.